NOTE: After powering on an EX3200 or EX4200 switch, wait for at least 60 seconds
before powering it off. After powering off an EX3200 or EX4200 switch, wait for at
least 60 seconds before powering it back on.
After an EX3200 or EX4200 switch has been powered on, it can take up to 60 seconds
for status indicatorssuch as LEDs on the power supply, show chassis command
output, and messages on the LCDto indicate that the power supply is functioning
normally. Ignore error indicators that appear during the first 60 seconds.
Related Topics AC Power Cord Specifications for EX3200 and EX4200 Switches on page 98
AC Power Supply LEDs in EX3200 and EX4200 Switches on page 29
DC Power Supply LEDs in EX3200 and EX4200 Switches on page 30
Rear Panel of an EX3200 Switch on page 9
Rear Panel of an EX4200 Switch on page 11
Field-Replaceable Units in EX3200 and EX4200 Switches on page 16
Power Specifications for EX3200 and EX4200 Switches on page 97
Prevention of Electrostatic Discharge Damage on EX Series Switches on page 236
Connecting AC Power to an EX3200 or EX4200 Switch on page 146
Connecting DC Power to an EX3200 or EX4200 Switch on page 148
Connecting Earth Ground to an EX Series Switch on page 141
AC Power Supply LEDs in EX3200 and EX4200 Switches
The AC power supply in an EX3200 or EX4200 switch is on the rear panel. Table 13
on page 29 describes the LEDs on the AC power supplies in EX3200 and EX4200
switches.
Table 13: AC Power Supply LEDs in EX3200 and EX4200 Switches
State and DescriptionLED
OffDisconnected from power or power is not coming
into the power supply.
OnPower is coming into the power supply.
AC OK
OffPower supply is not sending out power correctly.
OnPower supply is sending out power correctly.
DC OK
AC Power Supply LEDs in EX3200 and EX4200 Switches 29
Chapter 2: Component Descriptions
Vue de la page 54