Cabling ERX Routers
Figure 27: ERX-310 Router, Rear View (DC Model)
Ground
Power B
switch
DC power
input B
DC power
input A
Power A
leads
POWER B
POWER A
-48VDC RTN
ON
|
O
OFF
-48VDC RTN
ON
|
O
OFF
Power A
switch
g013753
ERX-310 Ro
uter (AC Model)
1. Insert the
power cord into the AC power IEC receptacle. (See Figure 28.)
2. Insert the other end o f the power c ord into an appropriate AC powe r source.
NOTE: To provide redundancy, do no t terminate Power A and Power B leads at the
same power source.
3. Repeat Steps 1–2 for the other power input module, if needed.
Figure 28: ERX-310 Router, Rear View (AC model)
Ground
AC power input A
with switch
AC power input B
with switch
POWER A POWER B
100-240V ~ 5A
50/60 Hz
|
O
|
O
g013754
Cabling the Router for Power 65