Table 38: SRX210 Services Gateway Chassis Alarm Conditions and
Corrective Actions
Alarm
SeverityActionAlarm ConditionComponent
Amber
(minor)
If the internal flash memory fails at startup,
the services gateway automatically boots
from the alternative boot device (USB
storage device).
NOTE: If you configured your services
gateway to boot from an alternative boot
device, ignore this alarm condition.
Reformat the internal flash memory, and
install a bootable image. (See the Initial
Configuration for Security Devices and
Monitoring and Troubleshooting for
Security Devices.)
If you did not configure the services
gateway to boot from an alternative boot
device, contact Juniper Networks Technical
Assistance Center (JTAC). See Juniper
Networks Technical Assistance Center” on
page 110.
The services
gateway boots from
an alternate boot
device.
Boot media
Red
(major)
Contact the Juniper Networks Technical
Assistance Center (JTAC). See Juniper
Networks Technical Assistance Center” on
page 110.
If you must replace the failed Mini-PIM, see
the SRX Series Services Gateways for
the Branch Physical Interface Modules
Hardware Guide for information about
replacing the Mini-PIMs.
A Mini-PIM has
failed.
Mini-Physical
Interface
Module
(Mini-PIM)
Copyright © 2013, Juniper Networks, Inc.106