Juniper-networks MX480 Manuel d'utilisateur Page 171

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 366
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 170
CAUTION: To prevent damage when storing FPCs:
Never lay an FPC component-side down.
Figure 78: Do Not Stack FPCs
Never stack an FPC under or on top of any other component (see Figure
78 on page 147).
Related
Documentation
MX480 Flexible PIC Concentrator (FPC) Description on page 16
MX480 FPC Terminology on page 143
Holding an MX480 FPC on page 144
Maintaining the MX480 Power Supplies
Purpose For optimum router performance, verify the condition of the power supplies.
Action On a regular basis:
Check the status of the power supplies by issuing the show chassis environment pem
command. The output is similar to the following:
user@host> show chassis environment pem
PEM 0 status:
State Online
Temperature OK
AC Input: OK
DC Output Voltage(V) Current(A) Power(W) Load(%)
59 0 0 0
PEM 1 status:
State Online
Temperature OK
AC Input: OK
DC Output Voltage(V) Current(A) Power(W) Load(%)
59 18 1062 42
Make sure that the power and grounding cables are arranged so that they do not
obstruct access to other router components.
147Copyright © 2013, Juniper Networks, Inc.