Table 43: Component LEDs on the Services Gateway (continued)
Possible Causes and
Corrective ActionsMeaningStateLED
Normal condition. No
action is required.
The device is receiving
power and is functioning
normally.
GreenPower LED
Normal condition. No
action is required.
The Power button has been
pressed and quickly
released.
Amber
Normal condition if the
services gateway is
switched off. No action is
required.
If you have not powered off
the services gateway, verify
that the AC power cord
from the power source to
the device is not damaged,
the socket is in working
condition, and the device
has an AC input voltage
between 110 and 240 VAC.
See Monitoring the
SRX210 Services Gateway
Power System on page 125.
The device is not receiving
power.
Off
The device is not part of the
chassis cluster setup.
OffHA LED
Normal condition. No
action is required.
The Mini-PIM is present and
detected by the device.
GreenMini-PIM LED
See Monitoring the
SRX210 Services Gateway
Using Chassis Alarm
Conditions on page 122.
The Mini-PIM is not present
or is not detected by the
device.
Off
Monitoring the SRX210 Services Gateway Components Using LEDs 121